102
Linearity
Linearity is not adjustable in the field. Call IES at (800) 541-0852 .
Error Codes
Display error code Cause or Correction
dashes pan not properly placed, or damaged cell
error 1 inadequate environment (vibration, air draft, etc) or defective
electronics
error 2 wrong weight in calibration
error 3 improper reference weight or number in piece counting mode
error 5 compatibility problem with internal software and external
peripherals
flashing zeroes wrong or misplaced pan, or electronics failure
Abort calibration adjustment stopped before finished